208/230V Outlets (36 C13/6 C19) L6-30P 10 ft. (3.05 m) Cord 0U 1.8m/70 in. Height TAA
Monitored - NEMA L6-30P - 6 x IEC 60320 C19, 36 x IEC 60320 C13 - 230 V AC - 0U - Vertical - Rack Mount - Rack-mountable - TAA Compliant
MSRP$1,137.00
$1,046.04*
Save 8%In stock: 49
*Government pricing. Buying for commercial use? Request a quote. Commercial pricing may differ.
Genuine Eaton through authorized distribution — NDAA §889 screened before checkout. TAA verified on request.
Country of origin is manufacturer-reported and can vary by production lot. Where TAA applies to your purchase, we verify the shipping unit's origin on request.
The PDUMNV30HV2LX 5.8kW Single-Phase Monitored PDU provides real-time remote monitoring of voltage, frequency and load levels via built-in network connection. By reducing the frequency of on-site visits, these advanced remote capabilities can save you money and reduce downtime.
The 0U PDU features 42 outlets (36 C13 and 6 C19) with included plug-lock insert sleeves to prevent cables from becoming accidentally disconnected. A 10-foot cord with NEMA L6-30P plug connects the PDU to a compatible AC power source, generator or protected UPS.
The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.
A digital ammeter allows you to monitor each load bank's current and the total connected PDU load in real time to ensure they remain well below maximum capacity with no danger of overload. The PDU mounts in 0U of space in EIA-standard 19-inch racks using the included toolless mounting buttons or the included rack-mounting brackets. Use the included PDUMVROTATEBRKT kit to install the unit with outlets facing the rear for better airflow or equipment access. More from the Manufacturer
Provides Advanced Network Monitoring Capabilities
Featuring a built-in, Java-free, HTML5-based LX Platform interface, the PDUMNV30HV2LX provides remote power monitoring via a secure network or Web browser. When used with optional EnviroSense2 environmental sensor modules (sold separately), it can also perform temperature/humidity and dry contact monitoring, providing IT personnel with enhanced oversight of facility power and environmental conditions. Up to three EnviroSense2 modules can be daisy-chained together. The PDUMNV30HV2LX supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Automated alerts via email or SNMP traps can be configured to warn against potential overload, power loss and downtime. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. DHCP/Manual configuration support provides the ability to have network settings automatically assigned or manually assigned via a permanent IP address.
Product Specifications
Distributes and Monitors Single-Phase 208/240V Power with No Java Required
Tripp Lite's PDUMNV30HV2LX 5/5.8 kW Single-Phase Monitored PDU is an efficient, cost-effective power distribution solution with remote monitoring capabilities. Its 42 outlets (36 C13 and 6 C19) are organized into two separate breakered load banks that can be monitored remotely or locally via the unit’s digital ammeter. Designed for users who prefer a Java-free interface, this PDU uses 208/240V single-phase input to distribute 200-240V single-phase output. The 10 ft. cord has a NEMA L6-30P plug.
Supports Real-Time Load and Power Status Monitoring
The PDUMNV30HV2LX is equipped with a digital ammeter that allows IT personnel to monitor the PDU’s total load in real time. This meter helps ensure the PDU is used at maximum capacity with no danger of overload. Outlets are split into two load banks; the ammeter reports current for each bank, as well as for the total connected PDU load.
Integrates Easily Into Your Existing Infrastructure
This PDU mounts vertically in a standard rack enclosure, occupying 0U in the rack, freeing up space for other equipment and promoting efficient airflow. It also supports toolless button-mount installation. An included PDUMVROTATEBRKT kit allows the PDU to be mounted with rear-facing outlets for improved airflow and equipment access. Plug-lock insert sleeves prevent cables from becoming disconnected accidentally.
Why Choose Tripp Lite?
Founded in 1922 in Chicago, Illinois, Tripp Lite is a leading manufacturer of products to power, protect, manage, house, cool, connect and mount your equipment. From the largest data center to the smallest home office, Tripp Lite products keep your equipment running effectively and efficiently. Whether you need to supply power to servers and have reliable battery backup, connect high-resolution video sources to displays and digital signs, or organize and secure IT equipment in rack enclosures, Tripp Lite has the complete solution. Plus, before and after your purchase, our Chicago-based, in-house technical support specialists are available to assist you by phone, email and live chat. With over 95 years of quality products and service, Tripp Lite is a brand you can trust.
Limited Warranty: 2 Year
We're dedicated to improving people's lives and the environment with power management technologies that are more reliable, efficient, safe and sustainable. Every day, all around the world, people depend on technology, transportation, energy and infrastructure to live and work. With rapid growth in electrification, an energy transition driven by climate change and explosive growth in connectivity, we’re well positioned to solve the world’s toughest electrical and mechanical power management challenges. Because that’s what really matters. And we’re here to make sure it works.
| General Information | |
|---|---|
| Manufacturer | Eaton Corporation |
| Manufacturer Part Number | PDUMNV30HV2LX |
| Brand Name | Eaton |
| Product Model | PDUMNV30HV2LX |
| Product Name | PDUMNV30HV2LX 42-Outlet PDU |
| Product Type | PDU |
| Management | |
| Management | Protocols: IPv4 IPv6 HTTP HTTPS SMTP SNMPv1 SNMPv2 SNMPv3 telnet SSH FTP DHCP NTP |
| Physical Characteristics | |
| Mounting Orientation | Vertical |
| Mount Type | Rack-mountable |
| Rack Height | 0U |
| Height | 70" |
| Width | 2.2" |
| Depth | 2.6" |
| Weight (Approximate) | 15 lb |
| Power Description | |
| Input Voltage | 230 V AC |
| Output Voltage | 200 V AC, 208 V AC, 240 V AC |
| Power Rating (Watt) | 5800 W |
| Input Current | 30 A |
| Technical Information | |
| PDU Type | Monitored |
| Phase | Single Phase |
| Plug/Connector Type | NEMA L6-30P |
| Receptacle Type | IEC 60320 C19, IEC 60320 C13 |
| Receptacle Detail | 6 x IEC 60320 C19, 36 x IEC 60320 C13 |
| Warranty | |
| Limited Warranty | 2 Year |
| Miscellaneous | |
| Package Contents |
|
| Country of Origin | Taiwan |
| TAA Compliant | Yes |
| Environmentally Friendly | Yes |
| Environmental Compliance | Restriction of Hazardous Substances (RoHS) |
Matched on Single phase · IEC C13