0U vertical rack PDUs
Rack PDUs that consume no rack units — the full-height 0U class, as each manufacturer states it. Filter by mounting, outlet count, receptacle mix, amperage and voltage.
Showing 24 of 2,057 0U PDUs
- EatonEaton 7.7kW Single-Phase Switched PDU with LX Platform Interface, 230V Output, IEC 309 32A Blue, 10 ft. (3.05 m) Cord, 0U, TAA - Switched - 4 x IEC 60320 C19, 20 x IEC 60320 C13 - 230 V AC - Network (RJ-45) - 0U - Vertical - Rack Mount - Rack-mountable - TAA CompliantPDUMV32HVNETLX
$1,602.00
$999.14
131 in stock - EatonEaton Universal-Input Basic PDU G4, 208V and 415/240V, 42 Outlets, Input Cable Sold Separately, End-Entry Input, 72-Inch 0U Vertical - Basic - Universal Input - 24 x IEC 60320 C13, 18 x IEC 60320 C39 - Network (RJ-45) - 0U - Vertical - Rack-mountable - VerticalEVBAGU23X-E
$1,793.52
$1,440.52
552 in stock - EatonTripp Lite by Eaton PDU 3.7kW Single-Phase 208/230V Monitored PDU - LX Platform 20 C13 4 C19 Outlets C20 Input with L6-20P Adapter 0U 1778mm Height TAA - Monitored - 20 x IEC 60320 C13, 4 x IEC 60320 C19 - 230 V AC - Network (RJ-45) - 0U - Vertical - MountRack-mountable - TAA CompliantPDUMNV20HVLX
$871.00
$543.23
138 in stock - EatonTripp Lite by Eaton PDU 28.8kW 220-240V 3PH Switched PDU - LX Interface Gigabit 30 Outlets IEC 309 63A Red 380-415V Input LCD 1.8 m Cord 0U 1.8 m Height TAA - Switched - IEC 60309 63A Red 3P+N+E - 24 x IEC 60320 C13, 6 x IEC 60320 C19 - 380 V AC, 400 V AC - Network (RJ-45) - 0U - Vertical - Rack Mount - Rack-mountable - TAA CompliantPDU3XEVSR6G63B
$2,684.00
$1,673.97
3 in stock - EatonTripp Lite by Eaton PDU 6.7kW 200-240V 3PH Switched PDU - LX Interface Gigabit 30 Outlets L21-20P Input Outlet Monitoring LCD 1.8 m Cord 0U 1.8 m Height TAA - Switched - NEMA L21-20P - 6 x IEC 60320 C19, 24 x IEC 60320 C13 - 230 V AC - Network (RJ-45) - 0U - Vertical - Rack Mount - Rack-mountable - TAA CompliantPDU3EVSR6L2120
$2,520.00
$1,571.69
16 in stock - ATEN TechnologyATEN NRGence 16-Outlets PDU - Basic - NEMA 5-15P - 16 x NEMA 5-15R - 120 V AC - 0U - Rack-mountablePE0116SA
$197.00
$141.36
15 in stock
Specifications are read from the manufacturer product title as supplied to us; where a value is not stated it is left blank rather than estimated. Every line is screened for TAA country-of-origin and NDAA §889 status before checkout.
About 0U vertical rack PDUs
0U is a rack-height class, and it means the strip occupies none. Instead of taking a horizontal slot between two servers, a 0U PDU mounts vertically in the channel behind or beside the rear rails and runs most of the height of the cabinet. Two things follow from that, and both are why it is the data-center default. The obvious one is that every rack unit stays available for equipment. The less obvious one is outlet proximity: a full-height strip puts a receptacle within a foot or so of whatever needs it, which shortens power cords, keeps the rear of the rack passable, and makes it possible to trace which cord belongs to which host without pulling the bundle apart.
Fit is the thing to confirm before ordering. A 0U strip needs a clear vertical channel — cable managers, deep chassis and side-mounted cable trays are the usual obstructions — plus the mounting hardware for your cabinet, which is frequently a per-manufacturer button or bracket rather than anything universal. Length matters too: a strip sized for a 42U cabinet does not belong in a 24U wall enclosure, and a short strip in a tall rack puts half the outlets out of reach. After that the electrical spec is the same conversation as any other PDU — input plug, nameplate amperage against your continuous load, and a receptacle mix that matches the cords you own. This page locks the 0U class as stated in the manufacturer's title; the mounting control stays on the filter rail, because a small number of rows state a rack height without stating an orientation.
FAQ
0U vertical rack PDUs questions
- What does 0U mean on a PDU?
- That it consumes no rack units. A 0U PDU mounts vertically in the cabinet's side channel — behind or beside the rear rails — rather than horizontally between two pieces of equipment, so the full height of the rack stays available for gear. It is sometimes written zero-U, and often just called a vertical PDU.
- Will a 0U strip fit my rack?
- Check three things: that the vertical channel is clear of cable managers and deep chassis for the length of the strip, that you have the mounting hardware your cabinet needs (buttons and brackets are often manufacturer-specific rather than universal), and that the strip's length suits the cabinet height. A 42U-length strip in a short rack has nowhere to go; a short strip in a tall rack leaves the top of the cabinet reaching for extension cords.
- 0U vertical or 1U horizontal?
- Vertical for a rack that is full or heading that way, and for high outlet counts — a 0U strip carries far more receptacles than a 1U tray and costs no rack units to do it. Horizontal when the vertical channel is already occupied, when the cabinet is too shallow for a rear-mounted strip, or when the outlets genuinely need to be at the front for accessibility.
- Does this page show only vertical units?
- It shows the 0U rack-height class, read from the manufacturer's own title. Nearly every 0U PDU is a vertical strip, but a minority of rows state the height without stating an orientation and a small number state horizontal, so the Mounting control is left on the filter rail — set it to Vertical (0U) if you want only the rows that say so.
Kitting out a row of racks?
Send the cabinet make and height, the feed details and how many racks you are powering. We confirm the mounting hardware and receptacle mix, check stock across the quantity and return a complete quote.























