Best 0U Vertical Rack PDUs for Full-Height Cabinets
Vertical 0U power distribution that mounts in the cabinet's side channel instead of across the rails — read by outlet type and count, input plug and voltage, and whether the load reading has to leave the room.
0U vertical rack PDUs in stock at Uniqcli
How to choose →A curated selection with live pricing — in-stock lines first, then back-ordered lines with a typical lead time. Every line is sourced through US distribution and screened for NDAA §889 status before checkout, with TAA verified on request.
- ATEN TechnologyATEN NRGence 16-Outlets PDU - Basic - NEMA 5-15P - 16 x NEMA 5-15R - 120 V AC - 0U - Rack-mountablePE0116SA
$197.00
$164.57
15 in stock - EatonEaton Tripp Lite Series 1.92kW Single-Phase Local Metered PDU with ISOBAR Surge Protection, 120V, 3840 Joules, 28 NEMA 5-15/20R Outlets, L5-20P Input, 15 ft. Cord, 0U Vertical - Metered - NEMA 5-20P, NEMA L5-20P - 28 x NEMA 5-15/20R - 120 V AC - 0U - Vertical - Wall-mountable - RackPDUMV20-ISO
$405.00
$372.60
32 in stock - EatonTripp Lite by Eaton PDU 1.4kW 120V Single-Phase Switched Mini PDU - LX Platform Interface NEMA 5-15P 6 ft. (1.83 m) Cord 0U TAA - Switched - NEMA 5-15P - 2 x NEMA 5-15R - 120 V AC - 0U - Vertical - Under-counter Mount - Rack-mountable, Wall-mountable - TAA CompliantPDU15NETLX
$416.00
$382.72*
264 in stock - EatonTripp Lite by Eaton PDU 3.7kW 208/230V Single-Phase Basic PDU - 32 C13 & 6 C19 Outlets L6-20P Input 10 ft. Cord 63.75 in. 0U Rack - Basic - NEMA L6-20P - 32 x IEC 60320 C13, 6 x IEC 60320 C19 - 230 V AC - 0U - Vertical/Toolless - Wall-mountable, Rack-mountablePDUV20HVL6-72
$458.00
$421.36
227 in stock - EatonTripp Lite by Eaton PDU 2.9kW Single-Phase Basic PDU with ISOBAR Surge Protection 120V 3840 Joules 12 NEMA 5-15/20R Outlets L5-30P Input 15 ft. Cord 1U Rack-Mount TAA - Basic - NEMA L5-30P - 12 x NEMA 5-15/20R - 120 V AC - 0U/1U - Horizontal/Vertical - Rack-mountable, Wall-mountable - TAA CompliantPDUH30-ISO
$545.00
$501.40*
2 in stock - EatonEaton Tripp Lite Series 2.9kW Single-Phase Local Metered PDU with ISOBAR Surge Protection, 120V, 3840 Joules, 12 NEMA 5-15/20R Outlets, L5-30P Input, 15 ft. Cord, 1U Rack-Mount - NEMA L5-30P - 12 x NEMA 5-15/20R - 120 V AC - 0U/1U - Horizontal/Vertical - Wall-mountable - RackPDUMH30-ISO
$596.00
$548.32
8 in stock - EatonTripp Lite by Eaton PDU 3.7kW Single-Phase 208/230V Monitored PDU - LX Platform 18 C13 2 C19 Outlets C20 / L6-20P Inputs 0U 900mm Height TAA - Monitored - NEMA L6-20P, IEC 60320 C20 - 2 x IEC 60320 C19, 18 x IEC 60320 C13 - 230 V AC - 0U - Vertical - Rack Mount - Rack-mountable - TAA CompliantPDUMNV20HV2LX
$767.00
$705.64*
61 in stock
Entry basic 0U
Para Systems
Minuteman 18-port, 110V/12A, 48" 0U Vertical Mount
OEPD1815V48
Minuteman's 48-inch 0U vertical body with eighteen NEMA 5-15R outlets on a 120 V single-phase feed — the plain way to add a lot of outlets down the side of a cabinet without giving up a rack unit.
$123.32Back-orderedBasic 0U, 8-outlet
Vertiv
Vertiv Geist NSVKN080-101S15 8-Outlets PDU
13463
A Vertiv Geist basic 0U vertical PDU: eight NEMA 5-15R outlets on a 120 V input, mounted in the side channel for the network cabinet or small server rack that just needs clean, breaker-protected distribution.
$146.30Back-orderedBasic 0U vertical
Eaton
Tripp Lite by Eaton PDU 1.4kW 120V Single-Phase Basic PDU
PDUV15-48
A 1.4 kW Tripp Lite by Eaton 0U unit with sixteen NEMA 5-15R outlets and a 15-foot cord in a 48-inch vertical body — sized to run the length of a cabinet and reach the circuit without an extension.
$227.67In stockMetered 0U
Eaton
Tripp Lite by Eaton PDU 1.4kW Single-Phase Local Metered PDU 120V…
PDUMV15
A 1.8 kVA Tripp Lite by Eaton local metered 0U vertical unit: sixteen NEMA 5-15R outlets with a display at the rack, so the cabinet's load is a number you read instead of a limit you discover by tripping it.
$259.91In stockBasic 0U, C13/NEMA
PANDUIT
Panduit P16B04M Vertical Basic Power Distribution Unit
P16B04M
Panduit's vertical basic 0U PDU with sixteen NEMA 5-20R outlets on a 120 V single-phase feed — a clean distribution body for a server cabinet where the rack units are all spoken for.
$229.45Back-orderedMetered 0U, 26-outlet
CyberPower Systems
CyberPower PDU20MVT26F 100
PDU20MVT26F
A CyberPower 20 A metered 0U vertical PDU with twenty-six outlets on a NEMA L5-20P input and a ten-foot cord — the local reading plus the high outlet count a full-height cabinet run tends to need.
$227.89Back-orderedAPC basic 0U
Schneider Electric
APC NetShelter Basic Rack PDU, 0U, 15A, 100/120V, 14 NEMA 5-15 outlets
AP9567
An APC NetShelter basic 0U vertical unit: fourteen NEMA 5-15R outlets at 100/120 V behind overload protection, with a long cord to reach the circuit from the top or bottom of the cabinet.
$381.81In stockAPC 0U, C13 bank
Schneider Electric
APC NetShelter Basic Rack PDU, 0U, 16A, 208/230V, 15 C13 outlets
AP9572
An APC NetShelter basic 0U vertical PDU with fifteen IEC C13 receptacles on a 208/230 V input — the higher-voltage, detachable-cord answer for a rack of dual-corded server and network gear.
$475.26Back-ordered0U surge, AV rack
Legrand
Middle Atlantic NEXSYS Compact Power Distribution Unit
PDX-615C
A Middle Atlantic NEXSYS compact 0U unit with six NEMA 5-15R outlets and multi-stage surge protection, mountable in the rack or on the wall — sized for an AV rack or a shallow comms cabinet.
$355.56In stockMetered 0U, C13/C19
Legrand
Legrand 30-Outlets PDU
STV-2001K
A Legrand metered 0U vertical PDU with twenty-four IEC C13 and six C19 receptacles on a 230 V 63 A feed and branch-circuit protection — a high-count body for a densely dual-corded cabinet.
$808.43Back-orderedServer Tech basic 0U
Server Technology
Server Technology Low-Density Basic Power Distribution
CB-12H2-C20
A Server Technology low-density basic 0U unit with twelve IEC C13 receptacles on a C20 inlet at 230 V — the vendor's rack-mount distribution body for a cabinet that runs on detachable cords.
$148.35Back-orderedMonitored 0U, SNMP
CyberPower Systems
CyberPower PDU31116 Single Phase 100
PDU31116
A CyberPower monitored 0U vertical PDU: twenty outlets on a 120 V 15 A feed with SNMP, so the circuit's load is on the network with threshold alerts and a history rather than a display nobody is standing at.
$570.21Back-orderedSwitched 0U, per-outlet
ATEN Technology
ATEN eco PE6324LB 24-Outlets PDU
PE6324LB
An ATEN 0U switched PDU with metered-by-outlet reporting: twenty-one C13 and three C19 receptacles on a NEMA L6-30P input with a network port, for per-outlet power cycling and per-receptacle load data.
$813.28Back-orderedTAA switched 0U
ATEN Technology
ATEN NRGence PE6324LG 24-Outlet PDU-TAA Compliant
PE6324LG
An ATEN switched 0U PDU with twenty-one C13 and three C19 outlets on an IEC 60309 32 A input and a network port — the same class as the switched pick, ordered as the manufacturer's TAA part number.
Its title reads TAA Compliant. TAA and standard variants are different SKUs, so we screen and document the exact part number on the quote rather than the model family.
$892.06Back-orderedThree-phase switched 0U
CyberPower Systems
CyberPower PDU83102 3 Phase 200
PDU83102
A CyberPower three-phase 0U switched metered-by-outlet PDU: thirty outlets on a NEMA L21-20P input with an LCD, for a high-density cabinet that needs three-phase distribution and per-outlet control in the side channel.
$1,987.60Back-ordered42-outlet switched 0U
Server Technology
Server Technology PRO2 C2W42CE-DFME2M00 42-Outlets PDU
C2W42CE-DFME2M00
A Server Technology PRO2 0U switched PDU with forty-two IEC C13 receptacles on a Hubbell CS8365 input and a network interface — the full-cabinet, per-outlet-controlled body for a dense colocation or data-center rack.
$2,707.12Back-orderedBrowse all 4,095 PDUs
Not the right one above? Filter the whole range by the specs that matter — live pricing and honest availability on every row, the same NDAA §889 screening before checkout, and TAA verified on request.
Showing 24 of 4,095 PDUs
- EatonEaton 7.7kW Single-Phase Switched PDU with LX Platform Interface, 230V Output, IEC 309 32A Blue, 10 ft. (3.05 m) Cord, 0U, TAA - Switched - 4 x IEC 60320 C19, 20 x IEC 60320 C13 - 230 V AC - Network (RJ-45) - 0U - Vertical - Rack Mount - Rack-mountable - TAA CompliantPDUMV32HVNETLX
$1,602.00
$1,473.84
127 in stock - LegrandMiddle Atlantic NEXSYS Rack Mount Power Distribution Unit - 20 Amp, 9 Outlet Rack Mount PDU - Rack-mountable - RackPDX-920R
$482.00
$382.55
353 in stock - EatonTripp Lite by Eaton PDU 3.7kW Single-Phase 208/230V Monitored PDU - LX Platform 18 C13 2 C19 Outlets C20 / L6-20P Inputs 0U 900mm Height TAA - Monitored - NEMA L6-20P, IEC 60320 C20 - 2 x IEC 60320 C19, 18 x IEC 60320 C13 - 230 V AC - 0U - Vertical - Rack Mount - Rack-mountable - TAA CompliantPDUMNV20HV2LX
$767.00
$705.64
61 in stock - EatonTripp Lite by Eaton PDU 2kW 100-127V Single-Phase Basic PDU with ISOBAR Surge Protection - 3840 Joules 14 Outlets L5-20P Input (5-20P Adapter) 6 ft. Cord 1U - Basic - NEMA L5-20P, NEMA 5-20P - 2 x NEMA 5-15R, 12 x NEMA 5-15/20R - 120 V AC - 1U - Horizontal/Vertical - Rack-mountable, Wall-mountablePDUH20-ISO6
$343.00
$315.56
206 in stock
Specifications are read from the manufacturer product title as supplied to us; where a value is not stated it is left blank rather than estimated. Every line is screened for NDAA §889 status before checkout, with TAA verified on request.
Need pricing on 0U vertical rack PDUs?
Tell us where to reach you and a Uniqcli specialist will follow up by email with current pricing, availability and lead time for the quantities you need — including parts that aren’t shown on this page.
Buying for an organization or for yourself — both work. No payment up front.
0U means the PDU consumes no rack units: it mounts down the side channel of a full-height cabinet rather than across the rails, so the long bodies carry the highest outlet counts and face their receptacles at the equipment. Pick the tier by what you must do without walking to the rack — basic distributes, metered displays the load, monitored puts it on the network, switched cycles outlets.
A 0U vertical PDU is the answer when rack units are the resource you have run out of. Instead of eating a U across the rails, it mounts down the side channel of a full-height cabinet and runs the length of it, which is why the long bodies carry the highest outlet counts and face the receptacles at the equipment they feed. In a dense cabinet where every rack unit is spoken for by a server, a switch or a shelf, the vertical body is often the only place a PDU can go — and buying the height back later, by pulling equipment to fit a horizontal strip, is the expensive way to learn that. Everything selected here mounts vertically in the 0U channel; the sizing rules below decide which one belongs in the cabinet.
After the form factor come the same four questions every rack PDU answers, and they are a ladder of what you must be able to do without walking to the rack. A basic unit distributes outlets behind a breaker and nothing more, which is the whole requirement in a cabinet somebody visits anyway. A metered unit puts the circuit's load on a local display, so headroom is a number you read instead of a limit you trip. A monitored unit puts that reading on the network, where a threshold can raise an alert and a load history feeds capacity planning. A switched unit adds per-outlet control, so a hung device is power-cycled from wherever you are. Most rows name their tier in the title; where one names only its outlets, its breaker and its cord, treat it as distribution and confirm the rest on the quote. Then match the outlets to the equipment, the input plug and voltage to the circuit the facility provides, and the cord length to the run — and where a purchase order names TAA, read it on the exact part number, because TAA Compliant is titled on some of these rows and not others.
Buyer's checklist
How to choose a 0U vertical rack PDU
- Confirm the cabinet has a side channel and the depth a vertical body needs behind the equipment — the whole point of 0U is that it consumes no rack units, but it does need somewhere to sit.
- Pick the tier by what you must do remotely: basic for distribution, metered for a local load reading, monitored to put that reading on the network, switched for per-outlet power cycling. Buy the tier your operating model needs, not the one with the most features.
- Match the outlets to the equipment: count C13 and C19 receptacles against the detachable cords in the rack, and NEMA 5-15R or 5-20R against everything that arrives with a plug moulded on.
- Match the input plug, voltage and phase to the circuit the facility provides — these titles name inlets from NEMA 5-15P and L5-20P through L6-30P and IEC 60309 at 120 V, 208 V and 230 V, with three-phase rows for high-density racks.
- Count the outlets against the vertical run: a long 0U body carries far more receptacles than a 1U strip, so size for the whole cabinet's growth rather than adding a second unit later.
- Where the order names TAA, read it on the part number — TAA Compliant is titled on some rows here and not others, and it is a per-part fact to verify on the exact unit you order.
Why the side channel wins in a dense rack
The trade the 0U body makes is space for reach. A vertical unit gives up nothing in rack units — it mounts where nothing else can — and in return it asks for the cabinet's side channel and a little depth, and it puts its outlets slightly further from hand than a horizontal strip across the rails. In a fully-populated server cabinet that trade is almost always worth taking, because rack units are the scarce resource and the vertical run is the only free real estate left. Dual-corded equipment wants two of them, one down each side, fed from two circuits and balanced so either side can carry the rack alone if a feed fails. Standardize the part number per rack archetype — the same 0U unit in every server cabinet — and cord lengths, outlet maps, labels and spares collapse into one decision instead of twenty.
Sizing power, and buying it with the rack
Where a row names a kW rating, size against it and the branch circuit behind it; where it names none — many do not — the input plug and the voltage on the title are the sizing facts, and we confirm the kW with the quote. Keep the usual convention of staying near eighty percent of a continuously loaded circuit in mind, and confirm it with your facility's electrician rather than any product page, because the circuit, the breaker and the local code are what actually govern. Power is the part of a rack most often planned last and regretted first, so Uniqcli quotes the 0U PDUs together with the rack and cable management around them, the UPS or upstream distribution the room needs, the monitoring or DCIM licensing a networked unit implies, and the installation labour, on one order so the pieces arrive matched.
FAQ
Common questions
- What does 0U mean on a rack PDU?
- 0U — also written Zero U — means the unit consumes no rack units. Instead of mounting horizontally across the rails and eating a U, a 0U PDU mounts vertically in the side channel of the cabinet and runs its length. That is the whole reason to choose one: in a dense cabinet where every rack unit is already spoken for, the vertical body is often the only place a PDU can go, and its long run typically carries a higher outlet count than a horizontal strip. Check that the cabinet has the side channel and depth a vertical body needs before committing to it.
- Should I buy a basic, metered, monitored or switched 0U PDU?
- Decide it on what you must be able to do without walking to the rack. Basic distributes outlets behind a breaker, which is the whole requirement in a cabinet somebody visits anyway. Metered adds a local display so the circuit's load is a number you read rather than a limit you trip. Monitored puts that reading on the network for threshold alerts, dashboards and a load history. Switched adds per-outlet control so a hung device is power-cycled remotely. Most titles here name their tier; where a row names only its outlets, breaker and cord, treat it as distribution and confirm the rest on the quote.
- Can business, government and education buyers order these?
- Every line Uniqcli quotes is sourced through US distribution and screened for TAA country-of-origin and NDAA §889 status before checkout — with documentation tied to the specific part number, not a product family.