Best Cable Raceway and Wire Duct for Surface Runs
Channel, cover and the fittings that finish the run — PVC, steel and aluminium raceway for offices, classrooms, labs and racks, with live pricing on every card.
Cable raceway and wire duct in stock at Uniqcli
How to choose →A curated selection with live pricing — in-stock lines first, then back-ordered lines with a typical lead time. Every line is sourced through US distribution and screened for NDAA §889 status before checkout, with TAA verified on request.
- StarTech.comStarTech 6 ft 2 Piece Cable Raceway Duct, White, TAA - Cable raceway - 6 ft - whiteTC6W2
$24.59
$22.62*
446 in stock
10 ft LD10 channel
PANDUIT
Panduit Pan-Way LD10IW10-A LD Surface Raceway
LD10IW10-A
Panduit's Pan-Way LD10 surface raceway in off white, a 10-foot length of the larger LD profile — the workhorse channel for a multi-drop wall run in an office or classroom.
$41.25Back-ordered10 ft LD5 channel
PANDUIT
Panduit Pan-Way LD5WH10-A LD Surface Raceway
LD5WH10-A
The same Pan-Way system in the smaller LD5 profile, a 10-foot length in white — the size for one or two cables along a desk line or up to a single wall outlet.
LD5 and LD10 fittings are not interchangeable; order corners and tees for the profile you buy.
$32.13Back-orderedSolid-wall wiring duct
PANDUIT
PANDUIT 6ft Panduct Type FS
FS2X2LG6NM
Panduit's Panduct Type FS solid-wall raceway in light grey, 72-inch lengths supplied six to a pack — panel-grade duct for a cabinet or enclosure where the run is closed rather than slotted.
$36.58Back-orderedOverfloor base and cover
Legrand
Wiremold OFR Series
OFRBC-8
Wiremold's OFR overfloor raceway base and cover in black powder-coated steel and aluminium — the low walk-over profile for a cable crossing an open floor.
Overfloor profiles are their own product class; a wall raceway laid on the floor is a trip hazard.
$77.40*Back-orderedStainless 10 ft base
Legrand
Wiremold S4000 Raceway Base
S4000B
Wiremold's S4000 raceway base in stainless steel, a 10-foot length — the metal channel for corridors, plant rooms and clinical spaces where PVC takes too many knocks.
A base only: the S4000 covers are ordered separately, in precut lengths or full runs.
$53.78Back-orderedRack cable raceway
Legrand
Middle Atlantic Cable Raceway
MPR-3A
Middle Atlantic's 32-inch cable raceway in black powder coat — a short metal channel for dressing a bundle inside or alongside a rack rather than along a wall.
$119.06In stock2x2 in, 80 cables
StarTech.com
StarTech Cable Management Raceway with Cover 2"(50mm)W x 2"(50mm)H…
CBMWD5050
StarTech's 2-inch by 2-inch raceway with cover in a 6.5-foot length, slotted at 3/8 inch, rated to 80 cables in warp-proof UL 94V-0 PVC for surface or wall mounting.
Titled TAA and UL Listed by the manufacturer — a per-part designation, never a family rule.
$28.28*In stockOpen-slot wiring duct
StarTech.com
StarTech 2x2in Open Slot Wiring Cable Raceway Duct, Server Rack Cable…
AD2X2
StarTech's 2-inch by 2-inch open-slot wiring duct with a snap-lid, 5.6 feet long in warp-proof self-extinguishing PVC — the slotted kind for racks and panels, screw-mounted.
Titled TAA by the manufacturer — a per-part designation, never a family rule.
$31.11*In stock6 ft two-piece kit
StarTech.com
StarTech 6 ft 2 Piece Cable Raceway Duct, White, TAA
TC6W2
A StarTech two-piece cable raceway duct in white, 6 feet long — a straightforward base-and-cover length for a short desk or wall run.
Titled TAA by the manufacturer — a per-part designation, never a family rule.
$22.62*In stockInside corner, 20 pack
Eaton
Eaton Tripp Lite Series Raceway Inside Corner Connector, 20 Pack…
N080-C25-IC-WH
Tripp Lite by Eaton inside corner connectors in white ABS, twenty to a pack — a fitting, not a channel: the piece that turns a run into a wall junction without crushing the cable.
Titled TAA by the manufacturer — a per-part designation, never a family rule.
$37.28*In stockToolless end cap
Eaton
Tripp Lite by Eaton Toolless Raceway End Cap for Fiber Routing System…
SRFC10CAP
A toolless raceway end cap in yellow PVC for a 240 mm, 10-inch fiber routing system — a fitting that closes the end of a fiber raceway run without tools.
Fiber routing systems use their own fittings; this is not a cap for a general-purpose PVC wall raceway.
$20.64Back-orderedMore cable management in the Uniqcli catalog
See all 4,456 cable managementMore from across this category. In-stock lines lead, and a back-ordered line carries the same estimated availability its product page does — with live pricing throughout, NDAA §889 screening before checkout and TAA verified on request.
- LegrandMiddle Atlantic Cable Raceway - Cable Holder - Black Powder CoatSRCC
$279.00
$221.43
24 in stock - LegrandMiddle Atlantic Cable Raceway - Raceway - Black Powder Coat - 72" LengthMPR-8A
$200.00
$158.73
59 in stock - LegrandMiddle Atlantic Cable Raceway - Raceway - Black Powder Coat - 56" LengthMPR-6A
$176.00
$139.68
14 in stock - LegrandMiddle Atlantic Cable Raceway - Raceway - Black Powder Coat - 32" LengthMPR-3A
$150.00
$119.06
32 in stock - EatonEaton Tripp Lite Series Raceway Inside Corner Connector, 20 Pack, White, TAA - ABS PlasticN080-C25-IC-WH
$40.52
$37.28*
54 in stock - LegrandConnectrac Express On-Floor Kit - 12ft - TAA Compliant - Raceway - Silver - 12 ft LengthCTXPO112251CSV
$2,241.89
$1,976.97
Back-orderedBack-ordered — estimated OEM lead time 3–8 weeks (Oct 3 – Nov 7 if ordered today).
- LegrandConnectrac Express On-Floor Kit - 9ft - TAA Compliant - Raceway - Silver - 108" LengthCTXPO109251CSV
$2,137.67
$1,885.07
Back-orderedBack-ordered — estimated OEM lead time 3–8 weeks (Oct 3 – Nov 7 if ordered today).
- PANDUITPanduit Above Floor Raceway Table Leg Fitting, Black - Black - 1 PackAFR4TBLGBL
$375.92
$249.29
Back-orderedBack-ordered — estimated OEM lead time 3–8 weeks (Oct 3 – Nov 7 if ordered today).
- PANDUITPanduit Wyr-Grid Cable Raceway - Raceway - Gray - 62.99" Length - 1 PackWGTL12PG
$363.23
$240.86
Back-orderedBack-ordered — estimated OEM lead time 3–8 weeks (Oct 3 – Nov 7 if ordered today).
- LegrandWiremold OFR Series Overfloor Raceway 4 Inch Poke-Thru Transition - Poke Thru Transition Fitting - Black Powder Coat - 12.19" Length - SteelOFRPT4
$937.33
$826.56
Back-orderedBack-ordered — estimated OEM lead time 3–8 weeks (Oct 3 – Nov 7 if ordered today).
- PANDUITPanduit 6x4 FiberRunner Channel - Raceway - Yellow - 78.74" Length - Polyvinyl Chloride (PVC) - 2 PackFR6X4YL2
$292.88
$194.74
Back-orderedBack-ordered — estimated OEM lead time 3–8 weeks (Oct 3 – Nov 7 if ordered today).
- PANDUITPanduit FiberRunner FR12X4YL6 12x4 Channel Cable Raceway Base - Raceway - Yellow - 1 PackFR12X4YL6
$290.64
$193.25
Back-orderedBack-ordered — estimated OEM lead time 3–8 weeks (Oct 3 – Nov 7 if ordered today).
- PANDUITPanduit FiberRunner FR12X4BL6 Cable Raceway Base - 25.7" Diameter - Raceway - Black - 72" Length x 25.7" Diameter - 1 PackFR12X4BL6
$290.64
$193.25
Back-orderedBack-ordered — estimated OEM lead time 3–8 weeks (Oct 3 – Nov 7 if ordered today).
- LegrandWiremold Ofr Series Overfloor Raceway 3 Inch Poke-Thru Transition - Poke Thru Transition Fitting - SteelOFRPT3
$783.22
$690.68
Back-orderedBack-ordered — estimated OEM lead time 3–8 weeks (Oct 3 – Nov 7 if ordered today).
- PANDUITPANDUIT Pan-Way TG-70 Surface Raceway System - Raceway - Off White - 10 PackTG70IW10
$260.20
$173.00
Back-orderedBack-ordered — estimated OEM lead time 3–8 weeks (Oct 3 – Nov 7 if ordered today).
- PANDUITPanduit Wyr-Grid Cable Raceway Divider - Divider - Gray - 1 PackWGDW4PG
$237.75
$158.09
Back-orderedBack-ordered — estimated OEM lead time 3–8 weeks (Oct 3 – Nov 7 if ordered today).
- PANDUITPanduit Fiberrunner Channel, 4X4 System, 2M Length, Yellow - Raceway - Yellow - 78.74" Length - Polycarbonate - 2FR4X4LYL2
$228.48
$151.91
Back-orderedBack-ordered — estimated OEM lead time 3–8 weeks (Oct 3 – Nov 7 if ordered today).
- PANDUITPanduit FiberRunner FR4X4BL6 Cable Raceway - Raceway - Black - 72" Length - 1 PackFR4X4BL6
$209.04
$138.99
Back-orderedBack-ordered — estimated OEM lead time 3–8 weeks (Oct 3 – Nov 7 if ordered today).
- PANDUITPanduit FiberRunner FRBC24X4YL Cable Raceway Coupler - Coupler - Yellow - 1 PackFRBC24X4YL
$206.52
$137.31
Back-orderedBack-ordered — estimated OEM lead time 3–8 weeks (Oct 3 – Nov 7 if ordered today).
- LegrandWiremold 6000 Take-Off Connector (6000-6000) Fitting - Cable Raceway Take Off Connector - Ivory - SteelV6074
$208.75
$157.80
Back-orderedBack-ordered — estimated OEM lead time 3–8 weeks (Oct 3 – Nov 7 if ordered today).
Need pricing on cable raceway and wire duct?
Tell us where to reach you and a Uniqcli specialist will follow up by email with current pricing, availability and lead time for the quantities you need — including parts that aren’t shown on this page.
Buying for an organization or for yourself — both work. No payment up front.
Cable raceway is what you use when the cable cannot go inside the wall. A retrofit office where the drops arrive at head height, a classroom where the panel went up after the building was finished, a lab bench, a floor crossing that people walk over, a rack where a bundle needs to be held and hidden — all of them are the same job: a channel fixed to the surface, a cover snapped or screwed over it, and a set of fittings that turn the corners without kinking the cable. It is unglamorous and it is the difference between an installation that looks finished and one that looks improvised.
Size the channel by what goes in it and by what will go in it later. The rows here run from a 19 mm by 11 mm strip that hides one or two patch cords behind a desk up to 3-inch by 4-inch duct that carries a bundle across a plant room. The reliable practice is to fill a channel to roughly half its capacity on installation: a raceway packed to the lid cannot take the next cable, and the next cable always comes. Bend radius is the second constraint and the one that quietly costs performance — a Cat6A run crushed into a tight corner fitting is a run whose test results will not match the specification it was installed to.
The third decision is the type of channel. Solid-wall raceway with a snap-on cover is the finished look for an office wall or a classroom: cables enter at the ends and at deliberate drop points. Open-slot wiring duct — the slotted kind used inside racks, panels and control cabinets — lets a conductor leave the channel anywhere along its length, which is exactly what you want where dozens of terminations fan out, and exactly what you do not want on a public wall. Overfloor raceway is a third shape entirely: a low, wide, walk-over profile for a cable crossing a room where nothing can be dropped from above. Cards carry live pricing and current availability from the catalog.
Buyer's checklist
How to choose raceway and wire duct
- Size the channel to about half full on the day it is installed. The rows here run from a 19 mm strip to 3-inch by 4-inch duct; filling one to the lid means the next cable needs a second run beside it, and there is always a next cable. Count the cables, add the growth, then pick the size.
- Respect bend radius at every corner and drop. Corner and tee fittings exist so a cable turns without being crushed; forcing a bundle around a square edge is how a certified copper run stops meeting the specification it was tested to. Order the fittings with the channel, not after.
- Choose solid-wall raceway for public surfaces and open-slot duct for panels and racks. Slotted duct lets a conductor exit anywhere along the run, which is right inside a cabinet where terminations fan out and wrong on an office wall where the point is a clean, closed line.
- Match the material and finish to the room. PVC is the default and takes paint; steel and stainless are for corridors, plant rooms and anywhere the channel takes knocks; aluminium sits between them. Check for a UL listing and a flame rating where the run passes through occupied space.
- Decide the fixing method before the order. Adhesive-backed raceway is fast and reversible on a clean, sound surface and unreliable on textured or dusty ones; screw-mounted channel is the answer for anything permanent, anything heavy and anything above head height.
- Plan floor crossings as their own product. A cable crossing an open floor needs a low, wide walk-over profile, not a wall raceway laid on its side — the profile is what keeps it from being a trip hazard and what lets a chair roll over it.
- Order the whole system in one pass: base, cover, couplers, inside and outside corners, tees, entrance ends, end caps and any junction boxes. A run held up for one fitting is a room that cannot be handed over, and the fittings are the line items most often left off a first quote.
Raceway, wiring duct and overfloor: three shapes, three jobs
Surface raceway is a closed channel with a cover, and it is what goes on a wall in a room people use. It comes in a range of profiles for a reason: a small strip behind a desk hides a monitor and network cable, a mid-size channel carries a handful of drops along a classroom wall, and the larger sections take a bundle across a corridor. Because the cover is solid, cables enter at the ends, at junction boxes and at deliberate drop points — which is exactly the discipline you want on a surface anyone can see or touch.
Open-slot wiring duct is the slotted version, and it lives inside racks, control panels and equipment cabinets. The slots let a conductor leave the channel anywhere, so a panel with dozens of terminations can be wired neatly with every cable taking the shortest sane path. Overfloor raceway is the third shape: a low, wide profile with a shallow ramp on each side, designed to be walked and rolled over. Each of the three is a poor substitute for the other two, and specifying the wrong one is the single most common raceway mistake — usually discovered when someone tries to close a lid over a bundle that was never meant to be in that channel.
Quoting a run, not a part
Raceway is sold in lengths and installed as a system. A single wall run needs the base and cover in the right size and colour, couplers wherever two lengths meet, an inside or outside corner at every change of direction, a tee wherever a branch leaves, an entrance end where the cable arrives, an end cap where it stops, and often a junction box where a device or outlet lands. Miss one fitting and the run is not finished; guess at the count and either the job stops or a box of surplus corners goes on a shelf.
Uniqcli quotes the raceway with the cable, the jacks and patch panels, the racks and the labelling that go with the same job, so a cabling project lands as one accountable order rather than four. Send the run lengths, the number and type of cables in each, the surface being fixed to, the finish you want and the corner count, and we will come back with the channel, the cover, the fittings, availability, lead times and volume pricing on the whole system.
FAQ
Common questions
- What size raceway do I need?
- Size it to the cables plus the growth, and aim to fill it about half full on installation day. Count what goes in now, add what is likely to follow, and pick a profile that takes both without pressure on the cover. The channels on this page run from a 19 mm by 11 mm strip that hides one or two patch cords behind a desk to a 3-inch by 4-inch section that carries a bundle across a plant room, with several intermediate sizes. A raceway packed to the lid cannot accept the next cable, and the second run installed beside the first always costs more than the larger channel would have.
- What is the difference between raceway and wiring duct?
- Raceway is a closed channel with a solid cover: cables enter at the ends, at junction boxes and at deliberate drop points, which is what makes it right for an office wall, a classroom or any surface people see. Open-slot wiring duct has slotted sides so a conductor can leave the channel anywhere along its length, which is what you want inside a rack, a control panel or an equipment cabinet where many terminations fan out at different points. Both appear on this page, and each is a poor substitute for the other in the other's place.
- Can raceway be installed with adhesive instead of screws?
- On the right surface, yes — several channels here ship with adhesive backing, and on clean, sound, smooth paint or laminate that is a fast, reversible and perfectly respectable installation for a light run. It is not the answer on textured, dusty, freshly painted or porous surfaces, above head height, on anything carrying real weight, or anywhere the run must survive being knocked. Screw-mounted channel is the default for permanent work, and mixing the two along one run tends to end with the adhesive section on the floor.
- What fittings do I need to order with a raceway run?
- More than most first quotes include. A finished run needs the base and cover in the right size, couplers wherever two lengths meet, an inside or outside corner at each change of direction, a tee wherever a branch leaves the main run, an entrance end where the cable arrives, an end cap where it stops, and a junction box wherever a device or outlet lands. Fittings are sold per system and are not interchangeable between profiles, so count the corners off the drawing before ordering — a run held up for one missing corner is a room that cannot be handed over.
- Can business, government and education buyers order these?
- Every line Uniqcli quotes is sourced through US distribution and screened for TAA country-of-origin and NDAA §889 status before checkout — with documentation tied to the specific part number, not a product family.
Need cable raceway and wire duct pricing?
Send a bill of materials or part numbers — we confirm stock and a below-market total, with TAA verified on request. No payment up front.

























































