Uniqcli

Check the entered optic pair basics

Compare nominal rates, media and crossed wavelengths while keeping exact host support explicit.

Networking

Check the entered optic pair basics

Compare nominal rates, media and crossed wavelengths while keeping exact host support explicit.

Example inputs · Replace these with your measurements to build your plan.

Method, example and sources
  1. Compare nominal port rates and fiber types at both ends.
  2. Check each transmitter against the opposite receiver's nominal wavelength.
  3. Record exact host, optic, software and configuration support separately.
  4. Carry the pair into loss and polarity checks before specification.

Worked example. A 1310 nm transmit and 1550 nm receive unit needs the complementary nominal pair in the reverse direction; identical transmit labels are not enough for that example.

Planning result · confirm model details

Entered pair basics align

Nominal rate, media and crossed wavelength checks are separate from exact host support.

Basic matching checks
4of 4
Nominal end A rate
10Gbps
Nominal end B rate
10Gbps
Documented host configurations
0of 2
Check the entered optic pair basics: detailed result
CheckResult
Nominal rateAligned
Fiber typeAligned
A TX matches B RXAligned
B TX matches A RXAligned
End A host supportunknown
End B host supportunknown
  • Nominal wavelength equality is only a screening check; actual TX/RX passbands and simplex/duplex/parallel path design must be verified.
  • Host software, port mode, vendor coding, temperature, reach, optical budget and connector polarity are not certified here.

Networking

Trace declared MPO fiber lane mappings

Compose declared straight, reverse and pair-flip mappings and inspect every lane at the far end.

Example inputs · Replace these with your measurements to build your plan.

Comma-separated A=straight, B=reverse, C=pair flip. Verify the actual vendor lane mapping; these names alone do not certify a channel.

Method, example and sources
  1. Choose the array size for the declared mapping model.
  2. List each documented straight, reverse or pair-flip component in connection order.
  3. Trace the chosen transmit lane through the complete sequence.
  4. Compare its far-end position with the intended receiver and review the full lane table.

Worked example. Two ideal reverse mappings compose to a straight mapping. One reverse mapping takes lane 1 to lane 12 in a declared 12-lane example.

Planning result · confirm model details

The traced lane reaches the entered receiver

A composition of the declared ideal mappings, not a physical cable test.

Lane count
12
Components
3
Transmit lane
1
Actual far-end lane
12
Required far-end lane
12
Trace declared MPO fiber lane mappings: detailed result
Near-end laneFar-end lane
112
211
310
49
58
67
76
85
94
103
112
121
  • Actual gender, key orientation, pin population, cassettes, lane numbering and parallel/duplex use must match the declared maps.
  • Optical loss, host coding and active lane assignments remain separate checks.

From the catalog

Transceivers/Media Converters

Explore related listings, then confirm the exact model requirements against your plan. These listings are not an automatic compatibility or capacity verdict.

A pair has two directions

The light transmitted by one endpoint must be acceptable to the receiver at the other. The screening table compares crossed nominal wavelengths as well as rate and fiber type. These are useful mismatch checks, but nominal labels are not the complete spectral passbands or a substitute for the manufacturer's application definition, connector layout and port mode.

Host support is a separate question

An optic can have matching media and rate while still being unsupported by a switch, adapter, software release or coding policy. Record exact model evidence at both ends; an unknown support state remains a review item. Reach, temperature, loss, overload, polarity and active lane requirements still need checking. An aligned basic table does not certify end-to-end interoperability or invent a supported model.

Worked example

A 1310 nm transmit and 1550 nm receive unit needs the complementary nominal pair in the reverse direction; identical transmit labels are not enough for that example.

Trace the channel instead of one cable

A fiber path can include multiple trunks, cassettes and patch leads. Their combined lane mapping determines where a transmit signal arrives. This worksheet composes three explicitly defined ideal permutations: straight, complete reversal and adjacent pair flip. It shows every lane, so an expected receiver can be checked without relying on a diagram copied from another product.

Verify what the component names mean

Actual key orientation, gender, pin population, lane numbering and active-lane allocation must match the vendor documents for every selected component. An A, B or C name alone does not establish a complete channel, particularly when duplex and parallel applications are mixed. The table is a declared mapping calculation, not an optical test or a host compatibility verdict; retain loss and coding checks separately.

Worked example

Two ideal reverse mappings compose to a straight mapping. One reverse mapping takes lane 1 to lane 12 in a declared 12-lane example.