Best Switched Rack PDUs for Remote Outlet Control
Network-managed PDUs with per-outlet relay control — 1U horizontal and 0U vertical, 120V and 208/230V single-phase, several with outlet-level metering and automatic transfer.
Switched rack PDUs in stock at Uniqcli
How to choose →A curated selection with live pricing — in-stock lines first, then back-ordered lines with a typical lead time. Every line is sourced through US distribution and screened for NDAA §889 status before checkout, with TAA verified on request.
- EatonTripp Lite by Eaton PDU 1.4kW 120V Single-Phase Switched Mini PDU - LX Platform Interface NEMA 5-15P 6 ft. (1.83 m) Cord 0U TAA - Switched - NEMA 5-15P - 2 x NEMA 5-15R - 120 V AC - 0U - Vertical - Under-counter Mount - Rack-mountable, Wall-mountable - TAA CompliantPDU15NETLX
$416.00
$382.72*
264 in stock - EatonTripp Lite by Eaton PDU 1.9kW Single-Phase Switched PDU LX Interface 120V Outlets (8 5-15/20R) NEMA L5-20P/5-20P input 12 ft. (3.66 m) Cord 1U Rack TAA - Switched - NEMA L5-20P/5-20P - 8 x NEMA 5-15/20R - 120 V AC - Network (RJ-45) - 1U - Horizontal - Rack Mount - Rack-mountable - TAA CompliantPDUMH20NET2LX
$1,029.00
$946.68*
322 in stock
Value 1U horizontal
Legrand
Middle Atlantic Essex Series Power Distribution Unit
PWR-9-RPM
The Middle Atlantic Essex is a horizontal 9-outlet, 15A switched strip with NEMA 5-15R receptacles — the low-cost way to put network outlet control on a rack of standard 120V gear.
$204.77In stock4-outlet eco
ATEN Technology
ATEN PE4104 4-Outlet Eco PDU Power Controller
PE4104A
The ATEN PE4104 eco PDU switches four NEMA 5-15R outlets over the network — a compact controller for a small rack or a remote cabinet where four scriptable outlets are all the job needs.
$264.72Back-ordered0U mini switched
Eaton
Tripp Lite by Eaton PDU 1.4kW 120V Single-Phase Switched Mini PDU
PDU15NETLX
The Tripp Lite by Eaton mini PDU is a 1.4kW 120V single-phase switched 0U unit on the LX platform — per-outlet control on the rear rail where a horizontal PDU would spend a rack unit it does not have.
$382.72*In stockSwitched + metered
Vertiv
Liebert MPH2 Metered Outlet Switched Rack Mount PDU
PD2-202
The Vertiv Liebert MPH2 is a switched-and-metered rack PDU (30A, 208/120V single-phase) that reports draw per outlet while it switches them — the combination data-center capacity planning actually wants on one device.
$502.92In stock100-240V 8-outlet
CyberPower Systems
CyberPower PDU41004 Single Phase 100
PDU41004
The CyberPower PDU41004 is a 1U switched PDU that runs on 100–240V, so the same unit serves a 120V rack and a 208/230V one — eight outlets, an LCD and SNMP management for mixed-voltage sites.
$675.51In stockCompact 1U Raritan
Legrand
Raritan PXO-2401CR 4-Outlet PDU
PXO-2401CR
The Raritan PXO-2401CR is a compact 1U four-outlet switched PDU — outlet-level relay control in a short chassis for a shallow rack or a wiring closet with little depth to spare.
$857.69Back-orderedDual-source ATS
Eaton
Tripp Lite by Eaton PDU 1.4kW Single-Phase Switched Automatic Transfer…
PDUMH15ATNET
The Tripp Lite by Eaton PDUMH15ATNET is a switched automatic-transfer PDU: two inlets, one output, and a fast switch between feeds so a single-corded server survives the loss of one source — resilience a non-redundant host cannot give itself.
$1,053.40*In stockTAA 24-outlet
ATEN Technology
ATEN NRGence PE6324LG 24-Outlet PDU-TAA Compliant
PE6324LG
The ATEN NRGence PE6324LG is a 24-outlet switched PDU whose own title states TAA compliance — a mixed C13/C19, 32A unit for a dense rack where the acquisition needs the TAA marking on the part.
$892.06Back-ordered0U vertical
Legrand
Middle Atlantic ZeroU PDU
LP-61100
The Middle Atlantic ZeroU is a 15A, 8-outlet 0U switched PDU that mounts on the rear rail and spends no rack units — per-outlet control beside a densely populated cabinet's devices instead of a fixed strip.
$1,155.56In stock16-outlet value
CyberPower Systems
CyberPower PDU41116 Single Phase 100
PDU41116
The CyberPower PDU41116 is a 15A single-phase switched PDU with 16 outlets and network management — the economical way to put per-outlet remote control across a full rack of mixed 120V equipment.
$1,007.18In stock0U vertical 16
Para Systems
Minuteman RPM2016N1LCD 16-Outlets PDU
RPM2016N1LCD
The Minuteman RPM2016N1LCD is a 0U vertical 16-outlet switched PDU with an LCD and a network port — full-height outlet control for a populated cabinet, with a socket beside each device.
$1,051.82Back-ordered1U C13 standard
Schneider Electric
APC NetShelter Switched Rack PDU, 1U, 1PH, 3.7kW 230V 16A… - 8.17 ft
AP7921B
The APC NetShelter AP7921B is a 1U switched rack PDU with eight C13 outlets and per-outlet network control — the reference unit for a rack that needs scripted power-cycling and a clean management page without spending vertical rail space.
$1,446.25In stockGeist 1U
Vertiv
Vertiv Geist Switched Rack PDU with Next Generation IMD
VP5N21A1
The Vertiv Geist VP5N21A1 is a 1U, 20A, 120V switched rack PDU with twelve NEMA outlets and the next-generation IMD management module — hot-swappable monitoring and per-outlet control for a serviceable rack.
$1,361.69*Back-orderedMonitored + switched
PANDUIT
Panduit G6 MS PDU, 16AMP, (12)C13, (4)C19, IEC 60309 2P+E 6h
P16E27G
The Panduit G6 is a monitored-and-switched intelligent PDU with twelve C13 and four C19 outlets on a 16A IEC 60309 inlet — per-outlet control and draw reporting on one high-density unit for a data-center rack.
$1,462.80Back-ordered24-outlet 0U pro
Server Technology
Server Technology PRO1 24-Outlets PDU
C1X24VS-DCFA11A1
The Server Technology PRO1 is a 24-outlet 0U switched PDU with eighteen C13 and six C19 receptacles — the vertical, high-density unit for a full rack of dual-corded gear on separate feeds.
$1,896.78Back-orderedMore rack PDUs in the Uniqcli catalog
See all 4,668 rack PDUsMore from across this category. In-stock lines lead, and a back-ordered line carries the same estimated availability its product page does — with live pricing throughout, NDAA §889 screening before checkout and TAA verified on request.
- EatonTripp Lite by Eaton PDU 10kW 200-240V 3PH Switched PDU - LX Interface Gigabit 30 Outlets L21-30P Input LCD 3 m Cord 0U 1.8 m Height TAA - Switched - NEMA L21-30P - 24 x IEC 60320 C13, 6 x IEC 60320 C19 - 230 V AC - Network (RJ-45) - 0U - Vertical - Rack Mount - Rack-mountable - TAA CompliantPDU3EVSR10L2130
$3,058.00
$2,813.36*
6 in stock - EatonEaton Tripp Lite Series 28.8kW 220-240V 3PH Switched PDU - LX Interface, Gigabit, 30 Outlets, Hardwire 380-415V Input, LCD, 1.8 m Cord, 0U 1.8 m Height, TAA - Switched - Hardwired - 6 x IEC 60320 C19, 24 x IEC 60320 C13 - 380 V AC, 400 V AC, 415 V AC - 0U - Vertical - Rack Mount - Rack-mountable - TAA CompliantPDU3XEVSRHWB
$2,798.00
$2,574.16*
8 in stock - EatonTripp Lite by Eaton PDU 6.7kW 200-240V 3PH Switched PDU - LX Interface Gigabit 30 Outlets L21-20P Input Outlet Monitoring LCD 1.8 m Cord 0U 1.8 m Height TAA - Switched - NEMA L21-20P - 6 x IEC 60320 C19, 24 x IEC 60320 C13 - 230 V AC - Network (RJ-45) - 0U - Vertical - Rack Mount - Rack-mountable - TAA CompliantPDU3EVSR6L2120
$2,520.00
$2,318.40*
16 in stock - EatonTripp Lite by Eaton PDU 2.9kW Single-Phase Switched PDU LX Platform Outlet Monitoring 120V Outlets (24 NEMA 5-15/20R) L5-30P Plug 0U TAA - Switched - NEMA L5-30P - 24 x NEMA 5-15/20R - 120 V AC - 0U - Vertical - Rack Mount - Rack-mountable - TAA CompliantPDUMVR30NETLX
$2,185.00
$2,010.20*
13 in stock - EatonTripp Lite by Eaton PDU 7.7kW Single-Phase Switched Automatic Transfer Switch PDU Two 200-240V IEC309 32A Blue Inputs 16-C13 2-C19 Outlets 2U TAA - IEC 60309 32A BLUE (2P+E) - 16 x IEC 60320 C13, 2 x IEC 60320 C19 - 230 V AC - 7.40 kVA - 1U/2U - Horizontal RackmountPDUMH32HVATNET
$2,013.00
$1,851.96*
138 in stock - EatonTripp Lite by Eaton PDU 1.9kW Single-Phase Switched PDU LX Platform Outlet Monitoring 120V Outlets (24 NEMA 5-15/20R) L5-20P Plug 0U TAA - Switched - NEMA 5-20P, NEMA L5-20P - 24 x NEMA 5-15/20R - 120 V AC - 0U - Vertical - Rack Mount - Rack-mountable - TAA CompliantPDUMVR20NETLX
$1,981.00
$1,822.52*
30 in stock
Need pricing on switched rack PDUs?
Tell us where to reach you and a Uniqcli specialist will follow up by email with current pricing, availability and lead time for the quantities you need — including parts that aren’t shown on this page.
Buying for an organization or for yourself — both work. No payment up front.
A switched rack PDU puts each outlet behind a relay the unit can open and close over the network, so a hung device is power-cycled from a script instead of a site visit, a decommissioned server's outlet is turned off rather than left live, and a start-up order can be sequenced. Several units are switched and metered, reporting draw per outlet as well.
A switched PDU is the piece of rack power you buy so you never have to send someone to the cabinet. Each outlet sits behind a relay the PDU can open and close over the network, so a hung appliance gets a scripted power-cycle instead of a truck roll, a decommissioned server's outlet is turned off rather than left live, and a startup sequence can be ordered so storage comes up before the hosts that mount it. The units below all carry 'Switched' in their own product titles — the outlet-level control is a documented capability, not an inference from the category.
The first decision is form factor and phase. A 1U horizontal PDU mounts in the rack's U-space and suits a cabinet with spare rack units and a modest outlet count; a 0U vertical PDU runs the full height of the cabinet rail and puts a socket beside almost every device, which is what a densely populated rack needs. Voltage follows the load: 120V single-phase covers most mixed IT racks, while 208/230V single-phase serves the higher-draw and international kit, and reading the plug type and breakered capacity against the circuit feeding the cabinet is the check that keeps a rollout from tripping on day one.
Switched is one rung of a ladder worth knowing. A basic PDU only distributes power; a metered PDU adds a current reading so you can see how close a circuit runs to its limit; a switched PDU adds the per-outlet relay this page is about; and several units here are switched-and-metered, reporting draw per outlet so capacity planning and remote control live on the same device. A few add an automatic transfer switch, drawing from two feeds so a single-corded server survives the loss of one — the redundancy answer for kit that was never dual-corded.
Buyer's checklist
How to choose a switched rack PDU
- Confirm the capability in the title: 'switched' means each outlet sits behind a relay you can cycle over the network — the difference from a basic strip or a metering-only PDU, and the whole reason to buy this class.
- Match the form factor to the rack: a 1U horizontal PDU fits a cabinet with spare U-space and a modest outlet count, while a 0U vertical unit runs the rail's full height and puts a socket beside a densely populated rack's every device.
- Size the voltage and phase to the load: 120V single-phase covers most mixed IT racks, and 208/230V single-phase serves higher-draw and international equipment — read the plug type and breakered capacity against the circuit feeding the cabinet.
- Decide whether you also need per-outlet metering: a switched-and-metered PDU reports draw at each outlet, so capacity planning and remote control live on one device instead of two.
- Check the outlet mix and count: match C13/C19 and NEMA receptacles to the cords your equipment actually uses, and buy enough outlets that the PDU is not run at 100% on install day.
- Consider an automatic-transfer PDU for single-corded critical kit: an ATS model draws from two independent feeds and rides through the loss of one, which is the redundancy a non-redundant server cannot provide itself.
Horizontal 1U vs. vertical 0U
The form factor is a rack-geometry decision. A 1U horizontal PDU consumes a rack unit and presents its outlets across the front or rear face — the right choice for a cabinet with U-space to spare and an outlet count in the single digits to low teens, or where the PDU needs to sit at a fixed, reachable height. It is also the simpler unit to swap, because it mounts in the same rails as everything else in the rack.
A 0U vertical PDU runs the full height of the cabinet's rear rail and does not spend a single rack unit, which is exactly what a densely populated cabinet needs: a socket beside almost every device, short cord runs, and no fight for the U-space the servers want. The trade is that a vertical unit is sized to the cabinet — a taller rack wants a taller PDU — so it is chosen with the enclosure rather than added later. For a full rack of dual-corded gear, two vertical PDUs on separate feeds is the common redundant layout.
Switched, metered and automatic transfer
The capability ladder is worth stating plainly because the words are easy to blur. A basic PDU distributes power and nothing more. A metered PDU adds a current reading — at the inlet on a simpler unit, at each outlet on a better one — so you can see how close a circuit runs to its breaker before it trips. A switched PDU adds the per-outlet relay that lets you cycle, sequence and disable outlets from a management page or a script. A switched-and-metered PDU does both, which is the combination most data-center capacity planning actually wants, because the same device that turns an outlet off also tells you what it was drawing.
Automatic-transfer PDUs sit slightly apart. An ATS model has two inlets fed from independent sources and switches between them fast enough that a single-corded load never notices the loss of one feed — the way to give a non-redundant server the resilience it cannot give itself, without rebuilding it with a second power supply. Where the equipment is already dual-corded, two ordinary switched PDUs on separate circuits is the simpler and usually cheaper redundant design; the ATS earns its place specifically for the single-corded exceptions.
Network management and lifecycle
A switched PDU is a network device, so it lives under the same discipline as the switches around it: a management address, firmware to keep current, and access control that decides who can cut power to a rack. Plan the out-of-band or management VLAN it lands on, and treat its firmware as part of the patch cycle rather than a set-and-forget appliance. A PDU is a long-lived asset that outlasts several server refreshes, and where a purchase has to satisfy sourcing rules, the same part numbers that carry the switched capability are the ones we screen for TAA country-of-origin and NDAA Section 889 status, tied to the exact SKU rather than a brand.
Related reading
FAQ
Common questions
- What is the difference between a switched, metered and basic PDU?
- A basic PDU only distributes power. A metered PDU adds a current reading — at the inlet or, on better units, per outlet — so you can see how close a circuit runs to its limit. A switched PDU adds a relay behind each outlet, so you can turn outlets on and off, cycle a hung device and sequence a startup over the network. Several units on this page are switched-and-metered, giving you remote control and per-outlet draw on the same device.
- Should I choose a 1U horizontal or a 0U vertical PDU?
- A 1U horizontal PDU spends a rack unit and suits a cabinet with spare U-space and a modest outlet count, or where you want the outlets at a fixed reachable height. A 0U vertical PDU runs the full height of the rear rail, spends no rack units, and puts a socket beside almost every device — the right choice for a densely populated cabinet. Because a vertical unit is sized to the enclosure, pick it with the rack rather than adding it later.
- When do I need an automatic-transfer (ATS) PDU?
- Use an ATS PDU for single-corded critical equipment. It draws from two independent power feeds and switches between them fast enough that a non-redundant server rides through the loss of one source. If your equipment is already dual-corded, two ordinary switched PDUs on separate circuits is the simpler redundant design; the ATS specifically covers the single-power-supply exceptions.
- What is a switched PDU?
- A switched PDU is a rack power distribution unit whose outlets each sit behind a relay that can be opened and closed over the network. That is what lets a frozen appliance be power-cycled remotely, an unused outlet be turned off rather than left live, and equipment be brought up in a defined order. A basic PDU only distributes power and a metered one only measures it.
- Can Uniqcli supply these PDUs for a government or education buyer?
- Every line Uniqcli quotes is sourced through US distribution and screened for TAA country-of-origin and NDAA §889 status before checkout — with documentation tied to the specific part number, not a product family.
Need switched rack PDUs pricing?
Send a bill of materials or part numbers — we confirm stock and a below-market total, with TAA verified on request. No payment up front.















































