Best Legrand PDUs for Data Center and Server-Room Racks

Switched, metered, and monitored rack PDUs in ZeroU (0U) and horizontal form factors, including RackLink-networked and DC power units.

Legrand rack PDUs in stock at Uniqcli

How to choose →

A curated selection with live pricing — in-stock lines first, then back-ordered lines with a typical lead time. Every line is sourced through authorized distribution and screened for TAA country-of-origin and NDAA §889 status before checkout.

Browse all 4,131 PDUs

Not the right one above? Filter the whole range by the specs that matter — live pricing and honest availability on every row, and the same TAA country-of-origin and NDAA §889 screening before checkout.

Showing 24 of 4,131 PDUs

Browse the full catalog

Specifications are read from the manufacturer product title as supplied to us; where a value is not stated it is left blank rather than estimated. Every line is screened for TAA country-of-origin and NDAA §889 status before checkout.

Need pricing on Legrand rack PDUs?

Tell us where to reach you and a Uniqcli specialist will follow up by email with current pricing, availability and lead time for the quantities you need — including parts that aren’t shown on this page.

Buying for an organization or for yourself — both work. No payment up front.

Do not submit classified information, CUI, restricted FCI, export-controlled technical data, protected health information, payment-card data, passwords, or private keys through this form. Contact your Uniqcli representative or [email protected] to request an approved channel.

Legrand's rack power distribution lineup on Uniqcli spans switched, metered, and monitored units in both ZeroU (0U) vertical and horizontal rack-mount form factors, plus DC power distribution and compact wall-mount options for edge cabinets. The selection shown here is sourced through authorized distribution, and each listing carries live in-stock status so you can plan around real availability rather than lead-time guesses.

Start from your circuit and your load. Input plug type and amperage — NEMA L5-20P, L5-30P, L6-20P, or L6-30P on the higher-density ZeroU units — has to match the receptacle feeding the rack, and the outlet mix (IEC C13 and C19 versus NEMA 5-20R) has to match your equipment cords. From there, decide how much control and visibility you need: switched PDUs give per-outlet on/off and remote reboot, metered units report load at the strip or per bank so you can balance phases and avoid overdraw, and monitored/RackLink units add remote alerting and integration without per-outlet switching.

Every unit is sourced through authorized distribution and screened for TAA country-of-origin and NDAA 889 status before checkout, with documentation tied to the specific part number. Certain Legrand ZeroU models are manufacturer-marked TAA compliant; where a build must meet that requirement, confirm it against the exact part number rather than the product family, since input and outlet variants differ across the range.

Buyer's checklist

How to choose a Legrand rack PDU

  • Match the input plug and amperage to your rack circuit — confirm the NEMA plug type (L5-20P, L5-30P, L6-20P, L6-30P) and the 20A or 30A rating against the feed before ordering.
  • Pick the intelligence tier that fits your operations: switched for per-outlet control and remote reboot, metered for load visibility and phase balancing, monitored for alerting without switching.
  • Confirm the outlet count and type — IEC C13/C19 for servers and network gear, NEMA 5-20R for mixed equipment — matches your existing cord inventory.
  • Choose the form factor: ZeroU (0U) vertical to preserve U-space in dense cabinets, or a horizontal 1U/2U strip where it is easier to reach and service.
  • Verify network manageability (RJ-45) and any RackLink or environmental monitoring you plan to integrate with your remote management tooling.
  • Where TAA sourcing is required, confirm compliance against the specific part number and request the country-of-origin documentation tied to that SKU.

Matching the tier to how the rack is staffed

The right intelligence tier usually follows how quickly a person can physically reach the rack. Unmanned edge cabinets — branch offices, retail back rooms, remote closets — justify switched units, because a remote per-outlet reboot recovers a hung device without dispatching anyone. Where staff are on-site but cabinets are filling up, the priority shifts to seeing real per-phase current, so load can be balanced before a breaker is stressed, which is where metered units earn their keep.

Facilities that want central alerting and environmental visibility, but not per-outlet switching they will never use, are the natural home for monitored and RackLink-networked units feeding a dashboard. DC distribution units serve a different world entirely — telecom, transport, and specialized head-end gear running on -48V rails. Sizing the tier to the operating model, rather than defaulting to the most featured strip, keeps spend proportional to how the rack is actually staffed and watched.

Capacity planning and headroom

Size the PDU to the circuit, then leave margin. A rack breaker should carry no more than about 80 percent of its rating as a continuous load, so a 20-amp circuit plans to roughly 16 usable amps and a 30-amp circuit to about 24. Total the nameplate draw — and better, the measured draw — of everything in the cabinet, then confirm the sum sits under that ceiling with room for the next switch or server you add.

For dual-corded equipment, put the A and B feeds on separate PDUs and separate upstream circuits, so either side can carry the full load if one drops — which means neither side should run past its own headroom in normal operation. On three-phase input, spread the high-draw devices across phases and let a metered or switched unit report per-phase current, so an imbalance surfaces on the dashboard before it becomes a nuisance trip.

Operational payback

The clearest return on an intelligent PDU is the site visit it avoids. A single remote reboot of a frozen device at an unmanned location can offset a meaningful share of the unit's value by removing one after-hours truck roll, and switched outlets let a help desk cycle power safely with no technician on the floor. Metering delivers a quieter return by heading off the overload trips that would otherwise take a whole cabinet down at once.

Networked units also fold into existing monitoring, so draw and alerts land in the same tooling as the rest of the rack — useful when you are documenting utilization for a capacity plan or a facilities review. Every unit is sourced through authorized distribution and screened for TAA country-of-origin and NDAA status against its specific part number, so the compliance record travels with the order rather than being reconstructed later during an audit.

FAQ

Common questions

What's the difference between switched, metered, and monitored Legrand PDUs?
Switched units let you turn individual outlets on, off, or reboot remotely over the network, which suits lights-out sites. Metered units report current draw at the strip or per bank so you can balance load and stay under breaker limits, but do not switch outlets. Monitored units focus on remote visibility and alerting. Match the tier to how hands-off the rack needs to be.
Should I use a ZeroU or a horizontal rack PDU?
ZeroU (0U) PDUs mount vertically in the rack's side channel and free up all your U-space for equipment, which suits dense server and network cabinets. Horizontal 1U/2U strips are simpler to reach and cable in shallower racks or where you have spare U-space. Both are available across the switched and metered ranges shown here.
Do these support remote power management?
The networked models include an RJ-45 management port, and switched units expose per-outlet control and reboot over the network; several also carry RackLink for monitoring and integration. Check the individual listing for the exact management feature set, since it varies by model and monitoring tier.
Do you support business, government, and education buyers?
Yes. Uniqcli supports business, government, and education buyers. Every Legrand PDU is sourced through authorized distribution and screened for TAA country-of-origin and NDAA 889 status before checkout, with compliance documentation tied to the specific part number so it can accompany your procurement records.